Sensing Device
|
Multi Frequency Microwave Transmit/Receive with Ultrasonics |
|
Measurement Range
|
0 - 90% moisture |
|
Accuracy
|
0.1 - 0.5% |
|
Measurement Characteristics
|
Linear Response |
|
Control Cabinet
|
Powder Coated |
|
C-Frame
|
Powder coated mild steel (MA-500 only) Option: S/Steel or Galvanized |
|
Operation of Unit
|
Full Penetration, Non contact continuous Real Time measurement |
|
IP/NEMA Rating
|
IP66/4X |
|
Ambient Temp Range
|
-5 to 60 degrees C (23 to 140 degrees F) |
|
Humidity
|
0 - 95% non condensing |
|
Supply Voltage to Cabinet
|
110/220V AC +/- 10% |
|
Int Electronics Power Supply
|
24V DC (12-30V DC) - Option: 24V DC supply |
|
Signal Outputs
|
2 x 4-20mA, 1 x RS232 (using modbus protocol). |
|
Measuring Depth Range
|
20 - 500mm## (model dependant) |
|
Analysis Times
|
100 times per second. Output 1 second increments. |
|
Signal to Noise Ratio
|
Each MoistScan® product is designed for a particular application so that the transmitted signal is clearly distinguishable from the noise from background Microwave radiation and electronics measurement techniques. |
|
Repeatability
|
0.1% at 1 STD DEV |
|
Dependencies
|
Callidan’s patented Microwave technique
when used in approved applications operates independent of transport speed, material profile, material color, particle size and temperature. |
| Options Available: |